Watson TDM
Operating Manual
Watson-TDM-Manual-W.doc
Version 2.0-01
8-28
Revision: 2008-02-07
STOPBER
A BER test can be terminated manually by this command.
READBER
The results of a BER test can be displayed using this command. When a test is
running, the current results are displayed, when no test is running, the results of
the last BER test are displayed.
LTU_01_PM> READBER
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
BER Test Results Test completed
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Test direction : SHDSL
Test interval : 180
Test pattern : 2^15-1
Test bitrate : 1984000
Bit errors : 0
Bit error rate : 0.00E+00
Sync loss seconds : 0
Elapsed seconds : 180
RESETBER
The RESETBER command resets the error and time counters of a BER test.