Watson Ethernet
Operating Manual
Watson-Ethernet-Manual.doc
Version 3.3-01
On the Watson Ethernet tabletop:
NTU_FMM_REMOTE> ALARM
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Local Alarm Status
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
LOOP1:off ACO:off LKINT:on
LOOP2:off ALB:off
LOSW-A:off BER-A:off SEG-A:off BERT:off
With ALARM T each change in the alarm status will be shown on the screen with
a time stamp counted in min:sec:millisec from the last system reset.
To deactivate alarm trace, enter ALARM T a second time or leave the FMM
menu.
Alarms (plug-in):
High bit error rate on DSL (CRC6 – faults)
DSL loss of synchronization word
Test loop active
DSL Fallback Alarm
Alarms (tabletop)
Analog loopback (Watson Ethernet tabletop only)
SDSL block-error-rate according G.826 30% on loops A/B
DSL loss of synchronization word on loops A/B